Manufacturing IT Services
A plant network is not an office network with machines attached
IT and OT for cement, aluminium, cables and food processing plants — designed, supplied and run by engineers based in Muscat. When a line stops, the clock is the only thing that matters.
Why plant IT is its own discipline
An office outage is an inconvenience measured in productivity. A stopped production line is measured in contribution per minute, idle crew, the restart ramp and the scrap that comes off it before the process is back in spec. The two problems are not the same size, and they are not solved the same way.
Most IT providers treat a plant as a larger office. They patch during the day, put the HMI on the same flat network as the accounts department, and cannot tell you where the PLC programs are backed up. We work the other way round: the process comes first, and the IT is designed not to interrupt it.
We support plants across Oman in cement, aluminium, cables, petrochemical services and food processing — and in Oman we can design, supply and run the whole stack rather than handing you a specification and leaving you to source it.
What is an hour of downtime actually worth on your line?
Before any conversation about redundancy, monitoring or backup is worth having, it helps to know the number you are protecting. Our calculator prices a stoppage the way a plant accountant would — lost contribution rather than revenue, the restart ramp, idle crew only when they truly are idle, and scrap at full cost.
It runs in your browser, takes about a minute, and gives you a figure per minute, per incident and per year. Most plants find the annual figure is the one that changes the conversation.
Plant IT and OT services
OT and ICS security
Segmentation between the business network and the plant floor, controlled vendor remote access instead of a permanent tunnel nobody audits, and firewall policy written around the process rather than against it. Delivered on Fortinet, which we design, supply and manage in Oman.
Plant network design
Cell-level segmentation along Purdue-model lines, industrial switching that survives the environment it is installed in, and addressing that leaves room for the next line rather than running out at the first expansion.
Historian and PLC backup
SCADA and historian data backed up and restore-tested, and — the one almost everyone misses — PLC and HMI programs held somewhere other than an engineer's laptop, with versions you can actually roll back to.
Monitoring that knows what matters
Alerting weighted to the process, not to server uptime. A disk filling on the historian at 2am is an incident; a test VM rebooting is not. Reports you can hand an auditor, from the same portal your team already uses.
Industrial CCTV
Coverage sized for production areas and incident investigation rather than generic perimeter security, with retention that matches your safety policy and storage sized for it properly.
Managed IT with plant-appropriate response
Helpdesk, patching and infrastructure management scheduled around production windows, with maintenance planned into shutdowns instead of imposed on running shifts.
The five things we see on almost every plant we walk into
One flat network
The HMI, the historian, the office printers and the guest Wi-Fi on the same broadcast domain. It works until something on the office side reaches the plant floor.
Permanent vendor access
A remote tunnel opened for a commissioning engineer three years ago, still open, unlogged, and reaching further into the process than anyone realises.
PLC programs on a laptop
The only copy of the logic running your line sitting on one machine, unbacked-up, and often belonging to someone who has since left.
Windows that cannot be patched
An HMI on an operating system the vendor will not certify past a given patch level — a real constraint that has to be designed around, not argued with.
Backups nobody has restored
Jobs reporting success for years with no test restore behind them. The first real test is the worst possible time to find out.
Talk to someone who has been inside a plant